You are here

Quality of Water Recovered from a Municipal Effluent Injection Well in the Floridan Aquifer System, Pompano Beach, Florida

Download pdf | Full Screen View

Date Issued:
1984
Summary:
The U.S. Geological Survey, in cooperation with the Florida Department of Environmental Regulation and the Broward County Utilities Department, conducted a sampling reconnaissance of secondary treated effluent recovered from a moderately saline zone of the Floridan aquifer system. The sampling was conducted in Pompano Beach, Florida. The primary purpose of this investigation and report was to measure and describe the variation in levels of selected physical and chemical variables during a 69 million gallon backflow of the injected effluent. The data collection was designed to provide background and furnish documentation of the general efficacy of recovery of injected treated municpal effluent. 40 samples of backflowed effluent were collected for selected analyses during the 69 million gallon backflow period. The sampling periods were March to August 1975 and April 1976 to March 1977.
Title: Quality of Water Recovered from a Municipal Effluent Injection Well in the Floridan Aquifer System, Pompano Beach, Florida.
37 views
15 downloads
Name(s): McKenzie, Donald J.
Irwin, G. A.
Florida Dept. of Environmental Regulation.
Broward County (Fla.) Utilities Dept.
Type of Resource: text
Issuance: multipart monograph
Date Issued: 1984
Publisher: U.S. Geological Survey
Place of Publication: Tallahassee, Fla.
Physical Form: print
Extent: iv, 23 p. : ill., maps ; 28 cm.
Language(s): eng
Summary: The U.S. Geological Survey, in cooperation with the Florida Department of Environmental Regulation and the Broward County Utilities Department, conducted a sampling reconnaissance of secondary treated effluent recovered from a moderately saline zone of the Floridan aquifer system. The sampling was conducted in Pompano Beach, Florida. The primary purpose of this investigation and report was to measure and describe the variation in levels of selected physical and chemical variables during a 69 million gallon backflow of the injected effluent. The data collection was designed to provide background and furnish documentation of the general efficacy of recovery of injected treated municpal effluent. 40 samples of backflowed effluent were collected for selected analyses during the 69 million gallon backflow period. The sampling periods were March to August 1975 and April 1976 to March 1977.
Identifier: 11018878 (oclc), fgcu_swfe_0265 (IID)
Note(s): by Donald J. McKenzie and G.A. Irwin ; prepared in cooperation with the Florida Department of Environmental Regulation and Broward County Utilities Department.
Bibliography: p. 23.
Subject(s): Water quality -- Florida -- Pompano Beach
Sewage disposal in the ground -- Florida -- Pompano Beach
Groundwater -- Florida -- Pompano Beach
Persistent Link to This Record: http://purl.flvc.org/fgcu/fd/fgcu_swfe_0265
Use and Reproduction: http://rightsstatements.org/vocab/NoC-US/1.0/
Host Institution: FGCU
Is Part of Series: Water-resources investigations report ; 84-4100.