You are here
Verification and Transfer of Thermal Pollution Model. Volume III: Verification of Three-Dimensional Rigid-Lid Model.
Loading the Internet Archive Bookreader, please wait...
- Date Issued:
- 1982-05
- Summary:
- Understanding the environmental impact of hot water discharge from the condenser of a steam power plant is of considerable importance in helping to preserve aquatic life and also the overall efficiency of the power plant. In recent years, with the improvement of computing facilities, a number of different types of mathematical models have been developed to predict such effects. These models, if properly calibrated are extremely useful in determining the complete environmental impact arising due to normal as well as abnormal operating conditions, which may be difficult to realise experimentally. This is particularly important with respect to estimating these adverse effects during the planning stages, thus helping to minimize them in the final construction.
Title: | Verification and Transfer of Thermal Pollution Model. Volume III: Verification of Three-Dimensional Rigid-Lid Model. |
![]() |
---|---|---|
Name(s): | University of Miami. Department of Mechanical Engineering | |
Type of Resource: | text | |
Genre: | Technical Report | |
Issuance: | monographic | |
Date Issued: | 1982-05 | |
Publisher: | United States. Department of Commerce. National Technical Information Service. | |
Physical Form: | electronic resource | |
Language(s): | English | |
Summary: | Understanding the environmental impact of hot water discharge from the condenser of a steam power plant is of considerable importance in helping to preserve aquatic life and also the overall efficiency of the power plant. In recent years, with the improvement of computing facilities, a number of different types of mathematical models have been developed to predict such effects. These models, if properly calibrated are extremely useful in determining the complete environmental impact arising due to normal as well as abnormal operating conditions, which may be difficult to realise experimentally. This is particularly important with respect to estimating these adverse effects during the planning stages, thus helping to minimize them in the final construction. | |
Identifier: | FI07053143 (IID), 1046279 (digitool), fiu:24857 (fedora), AAC5254QF | |
Note(s): | Electronic reproduction. [Florida] : State University System of Florida, PALMM Project, 2007. Mode of access: World Wide Web. Electronic version created 2007, State University System of Florida. | |
Subject(s): |
Heat -- Environmental aspects Thermal pollution of rivers, lakes, etc. |
|
Persistent Link to This Record: | http://purl.flvc.org/fcla/tc/feol/FI07053143.pdf | |
Persistent Link to This Record: | http://purl.flvc.org/fcla/tc/feol/FI07053143.jpg | |
Use and Reproduction: | http://rightsstatements.org/vocab/NoC-US/1.0/ | |
Host Institution: | FIU |